Application: | Communication |
---|---|
Type: | Single-mode Fiber |
Connection Structure: | No |
Material Shape: | Round Wire |
Allowed Lateral Pressure: | No |
Allowed Tensile Strength: | No |
Customization: |
---|
Suppliers with verified business licenses
Suppliers reviewed by inspection services.
Attributes | specification | ||
Dimensional Specifications | Cladding Diameter | 125.0±0.7 um | |
Cladding Non-Circularity | ≤0.7% | ||
Coating Diameter | 243±7 um | ||
Coating-Cladding Concentricity | ≤10 um | ||
Coating Non-Circularity | ≤6 % | ||
Core-Clad Concentricity | ≤0.5 um | ||
Fiber curl (radius) | ≥4 m | ||
Delivery length | 2.1-50.4( km/reel) | ||
Optical Specifications Optical Specifications | Mode-Field Diameter (MFD) | @1310nm | 9.2±0.4 um |
@1550nm | 10.4±0.6 um | ||
Attenuation | @1310nm | ≤0.34 dB / km | |
@1383nm | ≤0.34 dB / km | ||
@1550nm | ≤0.20 dB / km | ||
@1625nm | ≤0.24 dB / km | ||
Attenuation VS. Wavelength | @1285-1330nm, Ref. λ@1310nm | ≤0.04 dB / km | |
@1525-1575nm, Ref. λ@1550nm | ≤0.03 dB / km | ||
Point Discontinuity | @1310nm | ≤0.04 dB | |
@1550nm | ≤0.04 dB | ||
Polarization Mode Dispersion(PMD) | Maximum Individual Fiber PMD | ≤0.2 ps/(km1/2) | |
PMD Link Design Value (M=20, Q=0.01%) | ≤0.1 ps/(km1/2) | ||
Typical Value | 0.04 ps/(km1/2) | ||
Zero Dispersion Wavelength(λ0) | 1312±12 nm | ||
Zero Dispersion slope(S0) | ≤0.092 ps/(nm2.km) | ||
Dispersion in the range of wavelength | 1285~1339nm | ≥-3.4, ≤3.4ps/(nm.km) | |
1271~1360nm | ≥-3.4, ≤5.3 ps/(nm.km) | ||
Cable Cutoff Wavelength λcc | ≤1260nm | ||
Mechanical Specifications | Proof test | ≥9.0N, ≥1.0%, ≥100Kpsi | |
Dynamic stress corrosion susceptibility parameters (Nd) | ≥20 | ||
Coating strip force | Average | 1.5N | |
Peak | 1.3-8.9N | ||
Macrobend Loss | 1turn, Φ[email protected] | ≤0.05 dB | |
100 turns, Φ[email protected]&1550nm | ≤0.05 dB | ||
100 turns, Φ[email protected] | ≤0.05 dB | ||
Environmental Specifications | Temperature Dependence(-60ºC to +85ºC, @1550nm&1625nm) | ≤0.05 dB / km | |
Temperature Humidity Cycling(-10ºC to +85ºC, at 85%RH @1550nm&1625nm) | ≤0.05 dB / km | ||
Water Immersion(23±5ºC, 30 [email protected]&1625nm) | ≤0.05 dB / km | ||
Dry Heat Soak(85±2ºC, 30 [email protected]&1625nm) | ≤0.05 dB / km | ||
Damp Heat(85±2ºC, at 85%RH, 30 days @1550nm&1625nm) | ≤0.05 dB / km |